Ellisys Sense Suction MNRF

Ellisys Sense Suction MNRF

ELLISYS SENSE is a Suction fractional microneedle dual radiofrequency medical system, using electronically controlled matrices of sharp and thin gold-plated microneedles to quickly and accurately transfer energy to the target skin layer and create a volumetric network of coagulation points simultaneously at depths per injection thanks to a new function double shot. And with reduced pain thanks to suction.
The system works with non-insulated microneedles, which deliver RF energy along the entire length of the needles’ puncture into the epidermis and dermis, or with insulated microneedles, which allow the precise location of the desired depth of RF energy action only on their tip and the creation of the desired electrothermal effect on the target layers of the skin.

Unrivalled characteristics

Dual system: two radio frequencies: monopolar: 1 MHz, bipolar: 1 and 2MHz A matrix of thin, gold-plated microneedles with a negative pressure that holds the skin in line with the matrix so that the needles penetrate the soft skin precisely and with the least pain

High radio frequency power 1 MHz: 35 Watt, 2 MHz: 70 W

Double depth with a double shot
(Precision control of penetration depth by Step Motor)

Radiofrequency energy can be emitted twice at two depths during one microneedle injection. This significantly shortens the entire procedure. A matrix of thin, gold-plated microneedles with a negative pressure that holds the skin in line with the matrix so that the needles penetrate the soft skin precisely and with the least pain

Vacuum suction

Prevents skin folds during treatment. It ensures full contact between the needle tip and the skin. It guarantees precise penetration of microneedles and RF emission to the target depth. It helps the microneedles to penetrate only when the correct vacuum level is achieved. Easily enable or disable the feature according to user preferences.

Five different types of microneedle arrays

25 pins insulated – targets only the dermis, leaves the epidermis thermally intact, short recovery.

Indications:  scars (acne, post-surgery), enlarged pores, fine wrinkles, uneven skin tone, loose and sagging skin.

49 & 14  pin non-insulated – targets both epidermis and dermis, excellent for acne treatment. 

Indications: purulent and nodular acne (after comedone extraction), deep wrinkles, deep scars, loose and sagging skin.

36pins insulated – targets only the dermis & specifically the subcutaneous layer.

Indications:  Abdomen, Arms, Legs & Thighs

Precise RF Emission: 0.5 mm tip of the microneedle emits radiofrequency (RF), allowing for targeted treatment

Single Pin RF :

1 pin isolated – targets only the dermis, only 0.5mm tip emits RF. 

Indications: specially formulated to target sebaceous glands, refractory acne (especially nodular type), syringoma, milia, enlarged pores, blackheads, lower eyelid fat, infraorbital wrinkles.

Technical Specifications:
Rated Voltage AC 100-240V, 50/60Hz
Frequency 1 & 2 MHZ (Bi-polar & Mono-polar)
Length Mono-polar: 0.5mm - 5.0mm (Adjustment unit 0.1 mm)
Bi-polar: 0.5mm-3.5mm(14pin, 25pin, 49pin), 0.5mm~7.0mm(36pin) (Adjustment unit 0.1mm)
Interval Time Manual, 0.3s, 0.5s 1.0s, 1.5s, 2s, 2.55, 3s
Dimension 365(W) X 505(D) X 1555(H) mm
Weight 37KG

Quotation and introduction inquiry

We will provide you with detailed information.

Scroll to Top